{"id":4645,"date":"2026-11-01T21:36:54","date_gmt":"2026-11-02T09:36:54","guid":{"rendered":"https:\/\/footworklab.net\/?p=4645"},"modified":"2026-11-01T21:36:54","modified_gmt":"2026-11-02T09:36:54","slug":"15-gait-treadmill-f5lab","status":"publish","type":"post","link":"https:\/\/footworklab.net\/ar\/news\/4645\/","title":{"rendered":"A Gait Treadmill Changes the Capture, Not the Question: Setting a Protocol on the F5-LAB"},"content":{"rendered":"<div class=\"fwl-author\">\n<p><strong>About the author<\/strong> \u2014 FOOTWORK LAB is a manufacturer of foot assessment equipment and custom orthotic insoles, based in Ruichang, Jiangxi Province, China. Founded in 2014, with its own production plant in operation since 2018. We hold European Union certification and ISO quality system certification, and since our first Canton Fair we have shown our systems at industry events in Dubai, Vietnam, Brazil and Hong Kong, sitting down with clinic owners, footwear retailers and distributors face to face. <a href=\"\/our-factory\/\">See the factory<\/a> or <a href=\"\/certificate\/\">view certification<\/a>.<\/p>\n<\/div>\n<p class=\"fwl-lead\"><strong>A runner finishes a training block at a sports facility and the coach points at the instrumented treadmill: &#8220;Get on and walk for two minutes.&#8221;<\/strong> The runner hops on, grabs the handrail, stares down at the belt, and the facility ends up with a record nobody can compare to anything. Nothing about the equipment failed in that scene \u2014 what failed was the capture protocol around it. A gait treadmill changes the conditions of measurement long before it changes the question being asked: the belt sets the speed, the machine sets the rhythm, and the runner&#8217;s body answers to both. This guide is for the managers of rehabilitation hospitals, sports venues, podiatry clinics and gyms who are about to put an F5-LAB Dynamic Gait Detection System into a room, and who want the first capture and the fiftieth to belong to the same series.<\/p>\n<p>The F5-LAB manual names the system a Dynamic Gait Detection System \u2014 it measures and analyses pressure distribution and body posture during walking and running, automatically identifies the gait pattern and provides clinical gait parameters. Its four core functions are gait cycle detection and evaluation, motion posture assessment, dynamic pressure assessment analysis, and dynamic bipedal butterfly line analysis. The sections below stay inside that list and ask the practical questions around it: what the moving belt does to the person on it, how the hardware catches a session that never stops moving, and why the protocol you write down matters more than the device you buy. If you are still weighing a fixed walkway against a belt, our <a href=\"\/news\/3966\/\">pressure plate and gait treadmill comparison<\/a> covers that split separately.<\/p>\n<h2>Two minutes on the gait treadmill: what is actually happening to the runner<\/h2>\n<p>Start with the obvious difference from overground walking: the speed is given, not chosen. On the street a runner self-paces stride by stride; on the belt the machine holds a speed and the runner&#8217;s cadence gets pulled toward it. Most people settle within a short time, but that settling is itself part of the record. Begin capturing the moment their feet touch the belt and you will archive a person still adapting \u2014 shorter steps, guarded contact, a rhythm borrowed from the machine rather than found by the body.<\/p>\n<p>Then there is everything above the ankle. A first-time user reaches for the handrail without being asked; even a light fingertip touch shifts load off the feet and shows up in the pressure picture. Looking down at the moving belt drops the head, rounds the shoulders and changes the whole alignment the cameras are trying to record. Fear of the moving surface does the rest. None of this is noise to be filtered out \u2014 it is the capture environment, and it behaves differently from a walk across a fixed plate. The record is still valid; it is just a record of a person on a belt, and it should be captured, labelled and compared as exactly that.<\/p>\n<p>The practical consequence comes before the first session: decide what the operator says and does. Same instruction every time, handrail allowed or not allowed \u2014 pick one, same starting speed, and a fixed settling period that is not recorded. Facilities that skip this step end up with a folder of interesting pictures that cannot be stacked against each other, which is the most expensive kind of data to own.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/10\/89fdf90b99633fec5b47f532e0bd010e-36.jpg\" alt=\"F5-LAB Dynamic Gait Detection System in use - FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB F5-LAB Dynamic Gait Detection System. Measurement records only &#8211; clinical interpretation remains a professional judgement.<\/figcaption><\/figure>\n<h2>How the F5-LAB catches a session that never stops moving<\/h2>\n<p>On a fixed plate, capture happens in the moment a foot crosses the sensing area. On a belt there is no crossing \u2014 the foot lands on the sensing surface again and again, so the system must segment the stream itself. That is what the manual means by automatically identifying the gait pattern: the software lifts individual cycles out of a continuous walk or run and assembles the gait cycle detection and evaluation on top of them. The sensing layer is the same family used across our pressure systems \u2014 Sinmec Fabric flexible-fabric sensing built into the belt surface \u2014 reading dynamic pressure assessment analysis under both feet while the session continues.<\/p>\n<p>The two cameras on their brackets do the other half of the job. BodyftAi machine vision reads motion posture from the side and rear while the belt runs, and because camera frames and pressure frames are synchronised, the report can place an alignment image beside the pressure data for the same moment of the same cycle. A reader is no longer guessing what the hip or the knee was doing when the forefoot loaded \u2014 both views sit on one page.<\/p>\n<p>In our pre-sales calls, one misunderstanding keeps coming back: buyers picture an ordinary gym treadmill with a camera pointed at it. The demonstration changes their mind faster than any description, because the sensing is in the belt itself and the capture is continuous \u2014 at one trade show in Dubai a manager stood at the booth for a long while watching the butterfly line draw itself live under a walking visitor, then asked why his own club&#8217;s treadmill sessions had never produced anything comparable. The answer was hardware in the belt, and a protocol behind it.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/10\/89fdf90b99633fec5b47f532e0bd010e-33.jpg\" alt=\"F5-LAB Dynamic Gait Detection System in use - FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB F5-LAB Dynamic Gait Detection System. Measurement records only &#8211; clinical interpretation remains a professional judgement.<\/figcaption><\/figure>\n<p>Walking and running deserve a separate word, because the system supports both and the manual treats them as two states of the same machine \u2014 while a well-run facility files them as two records. Walking keeps at least one foot on the ground at all times; running inserts a flight phase where neither foot is in contact, which changes the timing of the cycle, the size of the loads and the questions the record can reasonably answer. A walking record at two different belt speeds answers a question about rhythm and load transfer. A running record answers a question about how the foot handles repeated ground contact at speed. Stacking a walking capture and a running capture side by side as if they were the same measurement is the fastest way to make both of them unreadable.<\/p>\n<p>So the protocol names the mode, the speed and the duration, and the report page is filed accordingly. A sports venue building a baseline across a season will keep walking records as one series and running records as another; a rehabilitation hospital may only ever run the walking series with certain patients and the running series with athletes returning to training. The hardware does not force the split \u2014 the discipline of whoever files the reports does. <a href=\"\/news\/3551\/\">What changes when both feet leave the ground<\/a> is worth reading before deciding which series your room actually needs.<\/p>\n<h2>The protocol that decides whether two records can be compared<\/h2>\n<p>List the variables a belt adds and the protocol almost writes itself. Speed: hold one value for a given series, or define a fixed ramp and record only after the top speed is reached. Adaptation: a fixed settling period that is never captured. Footwear: barefoot or shod, decided once, because a shoe changes everything the pressure film shows. Incline: level for routine records, with any slope session filed as its own event. Handrail: permitted, or fingertips only, or not at all \u2014 any of the three is workable, but the choice must be the same next month.<\/p>\n<p>Our engineers see both sides of this on support calls. On one WhatsApp group, a gym had accumulated months of sessions that looked inconsistent, and the cause was not the machine: records had been taken at whatever speed the operator chose that day, some barefoot and some in running shoes, one operator allowing the handrail and another not. Walking through the setup call by call, the engineers helped the gym write a one-page protocol, and from the next visit onward the records finally stacked. The hardware had been capable of a comparable series all along; the written routine was the missing piece. We would rather see a modest device with a fixed protocol than a better machine whose protocol changes every week \u2014 the series is the asset, and the capture standards behind it decide whether two records can be compared.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/10\/89fdf90b99633fec5b47f532e0bd010e-37.jpg\" alt=\"F5-LAB Dynamic Gait Detection System in use - FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB F5-LAB Dynamic Gait Detection System. Measurement records only &#8211; clinical interpretation remains a professional judgement.<\/figcaption><\/figure>\n<h2>What comes back on the screen, and how the next visit follows<\/h2>\n<p>The report assembles the four manual functions into one layout. The gait cycle view breaks the session into identified cycles with their phase timing. The dynamic pressure view shows the load film under each foot with left and right side by side. The butterfly line \u2014 the dynamic bipedal butterfly line analysis and evaluation in the manual&#8217;s wording \u2014 traces the pressure path of each foot mirrored across the midline, so the two trails spread like wings and their asymmetries are visible at a glance: a path that hugs the inside edge on one side and swings wide on the other says more than any single number on the page. Motion posture assessment places the camera-derived alignment beside it, and AI-assisted report generation turns the captured session into a document a non-specialist can follow while the professional keeps the interpretation. Where a buyer needs a particular report format or language layout, the software can be customised, and that work is quoted separately from the equipment.<\/p>\n<p>Follow-up then runs on the protocol, not on memory. Because each session is captured under the same written conditions, the second visit lands beside the first in the same layout, and the butterfly line from this month can be laid over the one from last month. That comparison \u2014 not the single capture \u2014 is what a record is for, and it is how a rehabilitation hospital documents a return-to-training pathway or a sports venue tracks a season without arguing about whose session was set up differently. The measurement record describes load distribution, alignment and timing; it does not judge them, and it never closes a case by itself.<\/p>\n<h2>Frequently asked questions<\/h2>\n<div class=\"fwl-faq\">\n<h3>Does the belt speed change the record, and should we ramp it?<\/h3>\n<p>Speed is part of the capture environment: the belt sets the rhythm and the runner&#8217;s cadence follows. The right answer is not a universal speed but a fixed one for each series, or a defined ramp with capture starting only after the target speed is reached. What breaks comparability is changing the speed between visits without noting it, because a record taken at one pace cannot be read fairly against a record taken at another.<\/p>\n<h3>Should captures be barefoot or in shoes on the F5-LAB?<\/h3>\n<p>Either works; mixing does not. A shoe sits between the sensor and the foot and changes what the pressure film and the butterfly line can show, so a series captured barefoot should stay barefoot and a shod series should stay shod. Most facilities capture the baseline barefoot and add a separate shod series only when the question involves the shoe itself. The decision belongs in the written protocol, not in the operator&#8217;s judgement on the day.<\/p>\n<h3>Why are walking and running filed as two separate records?<\/h3>\n<p>Running adds a flight phase where neither foot contacts the belt, which changes cycle timing and load behaviour, so the two states answer different questions. The F5-LAB captures both \u2014 gait cycle detection and evaluation runs in each mode \u2014 but a walking capture and a running capture are not the same measurement and should not be stacked in one comparison. Name the mode in the protocol and file each series on its own.<\/p>\n<h3>What do the two cameras actually add during a treadmill session?<\/h3>\n<p>The cameras, mounted on their brackets, feed BodyftAi machine vision so motion posture is recorded while the belt runs. Because camera frames and pressure frames are synchronised, the report places an alignment view beside the pressure data for the same moment of the same cycle. Without that pairing, a reader sees where load landed but has to guess what the leg above it was doing.<\/p>\n<h3>What is the butterfly line on the report?<\/h3>\n<p>It is the way the system draws the pressure path of each foot: the left and right trajectories mirrored across the midline so they spread like a pair of wings. The shape shows how the centre of pressure travels through each cycle, and differences between the two sides stand out immediately. It is a description of the path, not a verdict \u2014 the professional reading the record decides what it means for the person on the belt.<\/p>\n<h3>What is the minimum order and how is the F5-LAB supported?<\/h3>\n<p>The minimum order for equipment is one unit. Every unit is tested for seven days before dispatch and carries a twelve-month warranty against non-human damage with free parts. Support runs through a dedicated WhatsApp group with our engineers, remote assistance where a screen can be shared, and over-the-air updates for connected units. The shipment includes the main unit, the two cameras with brackets, the hub, cabling, manuals and the installation toolkit.<\/p>\n<\/div>\n<h2>What we would do next<\/h2>\n<p>Before the unit arrives, write the one-page protocol: mode, speed or ramp, settling period, footwear, incline and handrail rule, plus the exact sentence the operator says to every person who steps on. Send us that page with your room dimensions and the operator&#8217;s role, and we will tell you where the cameras need to stand and whether the layout supports the series you intend to run \u2014 the <a href=\"\/f5-lab-gait-running-platform\/\">F5-LAB gait and running platform page<\/a> gives the system overview to start from.<\/p>\n<p>If you already run sessions on a belt and the records are not stacking, the fix is usually the written protocol rather than new hardware; we are glad to review what your team does today. For the surrounding decisions \u2014 room, space and speed control \u2014 see <a href=\"\/news\/3786\/\">a gait treadmill in a clinical room<\/a>. Order, warranty and transit terms are on the <a href=\"\/faq\/\">FAQ page<\/a>, and our team answers specification questions through the <a href=\"\/contact\/\">contact page<\/a>.<\/p>\n<p class=\"fwl-disclaimer\"><em>This article is intended for professional and educational reference. It is not medical advice. Foot assessment equipment produces measurements and images; clinical interpretation and any decision about care remain the responsibility of a qualified professional. Certification scope is limited to the documentation we hold: European Union certification and ISO quality system certification.<\/em><\/p>\n<div class=\"fwl-related\">\n<h2>Related reading<\/h2>\n<ul>\n<li><a href=\"\/f5-lab-gait-running-platform\/\">F5-LAB Dynamic Gait Detection System: Product Overview<\/a><\/li>\n<li><a href=\"\/news\/3966\/\">A Pressure Plate and a Gait Treadmill Answer Different Questions About Walking<\/a><\/li>\n<li><a href=\"\/news\/3786\/\">A Gait Treadmill in a Clinical Room: Space, Speed Control and the Data It Produces<\/a><\/li>\n<li><a href=\"\/news\/3551\/\">Running Gait Analysis: What Changes When Both Feet Leave the Ground<\/a><\/li>\n<li><a href=\"\/news\/3798\/\">Postural Analysis: Why Capture Standards Decide Whether Two Records Can Be Compared<\/a><\/li>\n<li><a href=\"\/contact\/\">Contact FOOTWORK LAB: Send a Protocol or Ask a Setup Question<\/a><\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/footworklab.net\/15-gait-treadmill-f5lab\/#faqpage\",\n  \"mainEntity\": [\n    {\"@type\": \"Question\", \"name\": \"Does the belt speed change the record, and should we ramp it?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Speed is part of the capture environment: the belt sets the rhythm and the runner's cadence follows. The right answer is not a universal speed but a fixed one for each series, or a defined ramp with capture starting only after the target speed is reached. What breaks comparability is changing the speed between visits without noting it.\"}},\n    {\"@type\": \"Question\", \"name\": \"Should captures be barefoot or in shoes on the F5-LAB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Either works; mixing does not. A shoe sits between the sensor and the foot and changes what the pressure film and the butterfly line can show, so a series captured barefoot should stay barefoot and a shod series should stay shod. The decision belongs in the written protocol, not in the operator's judgement on the day.\"}},\n    {\"@type\": \"Question\", \"name\": \"Why are walking and running filed as two separate records?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Running adds a flight phase where neither foot contacts the belt, which changes cycle timing and load behaviour, so the two states answer different questions. The F5-LAB captures both, but a walking capture and a running capture are not the same measurement and should not be stacked in one comparison.\"}},\n    {\"@type\": \"Question\", \"name\": \"What do the two cameras actually add during a treadmill session?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The cameras feed BodyftAi machine vision so motion posture is recorded while the belt runs. Because camera frames and pressure frames are synchronised, the report places an alignment view beside the pressure data for the same moment of the same cycle.\"}},\n    {\"@type\": \"Question\", \"name\": \"What is the butterfly line on the report?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is the way the system draws the pressure path of each foot: the left and right trajectories mirrored across the midline so they spread like a pair of wings. It is a description of the path, not a verdict - the professional reading the record decides what it means.\"}},\n    {\"@type\": \"Question\", \"name\": \"What is the minimum order and how is the F5-LAB supported?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The minimum order for equipment is one unit. Every unit is tested for seven days before dispatch and carries a twelve-month warranty against non-human damage with free parts. Support runs through a dedicated WhatsApp group with our engineers, remote assistance and over-the-air updates for connected units.\"}}\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"A Gait Treadmill Changes the Capture, Not the Question: Setting a Protocol on the F5-LAB\",\n  \"author\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"about\": {\"@type\": \"Thing\", \"name\": \"Gait treadmill protocol\"},\n  \"mainEntityOfPage\": \"https:\/\/footworklab.net\/15-gait-treadmill-f5lab\/\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>On a gait treadmill the speed is set by the machine, the cadence follows the belt, and the handrail and gaze shape the posture on camera. This guide unpacks a two-minute capture on the F5-LAB Dynamic Gait Detection System: what the moving belt changes, why walking and running are two records, and why a written protocol decides whether two visits can be compared.<\/p>","protected":false},"author":1,"featured_media":4588,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-4645","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/posts\/4645","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/comments?post=4645"}],"version-history":[{"count":1,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/posts\/4645\/revisions"}],"predecessor-version":[{"id":4646,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/posts\/4645\/revisions\/4646"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/media\/4588"}],"wp:attachment":[{"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/media?parent=4645"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/categories?post=4645"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/footworklab.net\/ar\/wp-json\/wp\/v2\/tags?post=4645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}