{"id":3099,"date":"2026-10-15T15:30:57","date_gmt":"2026-10-16T03:30:57","guid":{"rendered":"https:\/\/footworklab.net\/?p=3099"},"modified":"2026-10-15T15:30:57","modified_gmt":"2026-10-16T03:30:57","slug":"posture-analyzer","status":"publish","type":"post","link":"https:\/\/footworklab.net\/es\/news\/3099\/","title":{"rendered":"Posture Analyzer: What Camera-Based Posture Capture Records in a Foot Assessment Room"},"content":{"rendered":"<div class=\"fwl-author\">\n<p><strong>About the author<\/strong> \u2014 FOOTWORK LAB is a manufacturer of foot<br \/>\nassessment equipment and custom orthotic insoles, based in Ruichang, Jiangxi Province, China.<br \/>\nFounded in 2014, with its own production plant since 2018. Certified to European Union and ISO<br \/>\nquality system standards. <a href=\"\/our-factory\/\">See the factory<\/a> or<br \/>\n<a href=\"\/certificate\/\">view certification<\/a>.<\/p>\n<\/div>\n<p class=\"fwl-lead\"><strong>Camera-based posture capture records where the body sits over the feet,<br \/>\nand it answers a question that pressure measurement alone cannot reach.<\/strong> A pressure<br \/>\nrecording describes load under the soles. It does not describe the position of the legs, the pelvis<br \/>\nor the shoulders while that load is being applied. Add a camera and that position becomes part of the<br \/>\nrecord, which turns two separate observations into one. For an assessment room, that is a genuine<br \/>\ngain, and it is the reason posture capture has moved from a specialist add-on to a standard part of<br \/>\nmany installations.<\/p>\n<p>FOOTWORK LAB manufactures foot assessment equipment at our own plant in Ruichang, Jiangxi<br \/>\nProvince, where we have produced since 2018, and camera-based posture and alignment capture is built<br \/>\ninto our platforms alongside pressure sensing. The <a href=\"\/x5-foot-scanner\/\">X5 system<\/a> is the<br \/>\nconfiguration in our range that gives foot, ankle and posture work the most room. This article covers<br \/>\nwhat posture capture records, how it relates to pressure data, and what buyers should decide before<br \/>\nchoosing a configuration.<\/p>\n<h2>What camera-based posture capture records<\/h2>\n<p>The principle is straightforward. One or more cameras observe the person from a defined position,<br \/>\nand software identifies and tracks body landmarks \u2014 the position of the feet, the ankles, the knees,<br \/>\nthe pelvis, the shoulders \u2014 across a capture. From those positions, the software describes how the<br \/>\nbody is arranged over its base of support.<\/p>\n<p>What it produces is a set of measurements and images describing position and its changes. It does<br \/>\nnot produce an explanation. A posture recording can state that a shoulder sits higher than the other,<br \/>\nor that the pelvis is level or not, or that the position changes when the person moves. It cannot<br \/>\nstate why, and it does not decide what should be done about it.<\/p>\n<p>The distinction between measurement and judgement matters here more than in almost any other part<br \/>\nof assessment work, because posture is a subject on which everyone has an opinion. A recording that<br \/>\nis presented as an explanation rather than a description invites the wrong kind of conversation. A<br \/>\nrecording presented as a description gives a qualified professional something concrete to reason<br \/>\nabout, and gives the person being assessed something visible to look at while the reasoning is<br \/>\nexplained.<\/p>\n<p>It is also worth being precise about terminology. Posture capture describes position.<br \/>\nForce-line alignment describes how load is transferred through the leg relative to the foot. Gait<br \/>\ncapture describes a sequence of loading during movement. All three are measurable, all three are<br \/>\nuseful, and they are not interchangeable terms.<\/p>\n<h2>How posture capture differs from pressure measurement<\/h2>\n<p>The two answer different questions, and the value of an installation that does both comes from the<br \/>\ncombination rather than from either half.<\/p>\n<p><strong>Pressure measurement<\/strong> records load under the sole. It describes where weight sits,<br \/>\nhow it distributes across the foot, and how that changes during movement. It is highly sensitive to<br \/>\nhow a person is standing or moving at the moment of capture.<\/p>\n<p><strong>Posture capture<\/strong> records position above the sole. It describes how the body is<br \/>\narranged over the feet, including the position of the legs and the upper body. It is sensitive to<br \/>\nposture, to clothing, to where the person looks, and to how long they have been standing.<\/p>\n<p>Used together, they allow a professional to see a position and its loading consequence at the same<br \/>\ntime. That is more informative than either alone, and it is why we build both into the same platform<br \/>\nrather than offering posture capture as a separate product. It also means the recording can be<br \/>\ndiscussed as one thing rather than two, which matters for how easily a client or patient follows the<br \/>\nconversation.<\/p>\n<p>One practical consequence deserves emphasis. Both measurements are sensitive to conditions, and a<br \/>\npressure recording taken in one posture is not comparable with one taken in another. This is not a<br \/>\nlimitation of the equipment; it is a property of measurement. The response is to standardise the<br \/>\ncapture conditions and record them, which is the same discipline that makes any assessment data<br \/>\ncomparable over time.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/10\/c0056ab70da26139c43588f3551c27d8-3.jpg\" alt=\"Foot assessment equipment in use \u2014 X5\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X5. Measurement data only \u2014 clinical interpretation remains a professional judgement.<\/figcaption><\/figure>\n<h2>What an assessment room does with posture data<\/h2>\n<p>Posture capture finds its way into four common uses, and recognising which apply to your setting<br \/>\nhelps determine the configuration you need.<\/p>\n<ul>\n<li><strong>Baseline recording.<\/strong> A record of position at the start of a course of work,<br \/>\nagainst which later recordings can be compared. This is the most common use and the one that places<br \/>\nthe least demand on the equipment.<\/li>\n<li><strong>Supporting a pressure finding.<\/strong> Where loading under the sole is the main<br \/>\nobservation, a posture record shows the position in which that loading occurred, which often makes<br \/>\nthe observation considerably easier to explain.<\/li>\n<li><strong>Monitoring change over time.<\/strong> Repeat recordings under consistent conditions,<br \/>\nreviewed at intervals. Comparison is where the record earns its value, and comparison depends<br \/>\nentirely on consistency.<\/li>\n<li><strong>Supporting a product specification.<\/strong> Where insoles or footwear are to be<br \/>\nspecified, a position record adds context to the loading and shape data that inform the design.<\/li>\n<\/ul>\n<p>In all four uses, the practical requirement is the same: the camera has to be in the same place<br \/>\nevery time, the person has to be in the same position, and the conditions have to be recorded. The<br \/>\nequipment is capable of far more variation than the routine needs; restraint in how it is used is<br \/>\nwhat produces usable data.<\/p>\n<h2>Where the camera goes, and why position matters<\/h2>\n<p>Posture capture is more sensitive to camera placement than pressure capture is to plate placement,<br \/>\nand this catches out first-time buyers.<\/p>\n<p>A camera looks from a position, and what it can describe depends on that position. A camera<br \/>\ndirectly behind the person describes the rear view; one beside them describes the side view; one in<br \/>\nfront describes the front view. Each view makes some relationships visible and hides others, and a<br \/>\nroom that uses a single set view is effectively choosing which questions it can answer.<\/p>\n<p>Three practical points follow. First, decide which views the routine requires and place the camera<br \/>\naccordingly rather than by convenience. Second, keep the placement set and mark it, so that a<br \/>\nrecording taken this month can be compared with one taken next year. Third, consider background and<br \/>\nlighting in the actual room rather than in a demonstration space; a recording is only as useful as<br \/>\nthe person&#8217;s position is clear within it.<\/p>\n<p>Distance is the fourth point, and it is usually decided by the room rather than by the equipment.<br \/>\nToo close and the recording cannot show the whole body; too far and detail is lost. Our own guidance<br \/>\nis to choose one placement per routine and test it thoroughly before going live, rather than<br \/>\nadjusting it afterwards based on individual recordings.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/10\/c0056ab70da26139c43588f3551c27d8-4.jpg\" alt=\"Foot assessment equipment in use \u2014 X5\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X5. Measurement data only \u2014 clinical interpretation remains a professional judgement.<\/figcaption><\/figure>\n<h2>Combining posture with pressure and alignment<\/h2>\n<p>Where a platform records pressure, posture and lower-limb alignment together, the three outputs<br \/>\nsupport each other in ways that are difficult to achieve with separate systems.<\/p>\n<p>The pressure record describes load. The posture record describes position. The alignment record<br \/>\ndescribes how the leg carries load relative to the foot. Presented together, they allow a<br \/>\nprofessional to move between what, where and how without leaving the same session, and to check<br \/>\nwhether the three are consistent with each other.<\/p>\n<p>Consistency between them is itself informative. Where the loading appears unremarkable and the<br \/>\nposture record shows a clear position difference, that combination raises a question. Where both<br \/>\npoint the same way, the observation is more robust. Neither situation is a conclusion, and both give<br \/>\na professional something specific to reason about, which is precisely the contribution measurement<br \/>\nequipment should make.<\/p>\n<p>Two habits make combined recording practical. Keep the sequence identical between sessions, so<br \/>\nthat a reviewer always knows which capture preceded which. And keep all the outputs of a session<br \/>\ntogether in one record, rather than storing posture images separately from pressure data, because<br \/>\nseparated outputs are rarely looked at together afterwards.<\/p>\n<p>One practical habit is worth adopting from the first week: keep a short written protocol for the room. Camera position, the sequence of captures, how long the person stands, what they are asked to wear and who operates the session. Six lines are enough. The protocol is what makes a recording taken next season comparable with one taken this one, and it is also what allows a colleague to run a session correctly when the usual operator is unavailable.<\/p>\n<h2>What posture capture cannot show<\/h2>\n<p>Being explicit about the boundary is part of an accurate specification.<\/p>\n<p>Posture capture describes position at a moment, under particular conditions. It does not explain<br \/>\nthe position, it does not describe what the person does the rest of the day, and it does not<br \/>\ndetermine what anyone should do about what is visible. It is affected by clothing, by where the<br \/>\nperson is looking, by fatigue, and by how long they have been standing. All of these are reasons to<br \/>\nstandardise the routine and to repeat recordings rather than to read a single session as a<br \/>\nstatement about a person.<\/p>\n<p>It also does not substitute for examination or history. A recording is one input among several,<br \/>\nand the qualified professional conducting an assessment decides how much weight it carries. Our own<br \/>\nwording is deliberate on this point: assessment equipment produces measurements and images, and any<br \/>\ndecision about a person&#8217;s care remains the responsibility of a qualified professional.<\/p>\n<p>We apply the same restraint to certification language. Our documentation covers European Union<br \/>\ncertification and ISO quality system certification, and we describe exactly that scope. We do not<br \/>\nextend the claim, we do not name or criticise competing products, and we do not quote figures for a<br \/>\nconfiguration in a general article, because an honest number depends on the specification, volume,<br \/>\nservice scope and destination. Buyers who want a figure get one against their own requirement.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/10\/c0056ab70da26139c43588f3551c27d8-5.jpg\" alt=\"Foot assessment equipment in use \u2014 X5\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X5. Measurement data only \u2014 clinical interpretation remains a professional judgement.<\/figcaption><\/figure>\n<p>Written down, the protocol also becomes something a supplier can help refine. When a team can describe its routine precisely, a configuration conversation turns into a specific discussion about placement and sequence rather than a general one about features.<\/p>\n<h2>Choosing a configuration for your room<\/h2>\n<p>Six decisions settle most of the specification.<\/p>\n<ol>\n<li><strong>Which views the routine requires.<\/strong> Rear, side, front or a defined combination.<br \/>\nThis is the first decision and it drives camera placement.<\/li>\n<li><strong>Whether posture is captured standing, moving, or both.<\/strong> Both is more informative<br \/>\nand asks more of the room.<\/li>\n<li><strong>How the capture area is arranged.<\/strong> Enough space for the whole body to be visible,<br \/>\nwith a background that keeps the person clear in the recording.<\/li>\n<li><strong>Who operates the system, and how many of them.<\/strong> At least two trained operators, so<br \/>\nthe routine survives staff absence.<\/li>\n<li><strong>Where the records go.<\/strong> Export formats, integration with existing documentation,<br \/>\nand interface language, agreed before ordering.<\/li>\n<li><strong>Support in year two.<\/strong> Who answers technical questions, through which channel, and<br \/>\nhow spare parts are supplied.<\/li>\n<\/ol>\n<p>On the last point, our answers are published rather than supplied on request. A twelve-month<br \/>\nwarranty covers non-human damage with free spare parts within that scope. Support runs through a<br \/>\ndedicated WhatsApp group with direct engineer access, remote assistance where the setting allows, and<br \/>\nover-the-air updates for connected units. Every machine is tested in-house during a seven-day testing<br \/>\nperiod before dispatch, and production runs at roughly three to five machines per day, a rate chosen<br \/>\nso that testing and inspection are done properly rather than nominally.<\/p>\n<p>On scale, the machine minimum order quantity is a single unit. That matters for a configuration<br \/>\nlike this, because posture capture is a routine that benefits from being trialled in the actual room,<br \/>\nwith the actual lighting and the actual staff, before a group standardises on it.<\/p>\n<h2>Frequently asked questions<\/h2>\n<div class=\"fwl-faq\">\n<h3>What does a posture analyzer actually record?<\/h3>\n<p>Camera-based capture identifies body landmarks and describes how the body is arranged over its base<br \/>\nof support: the position of the feet, ankles, knees, pelvis and shoulders across a capture. The output<br \/>\nis a set of measurements and images describing position, not an explanation of it.<\/p>\n<h3>Is posture capture a replacement for pressure measurement?<\/h3>\n<p>No, they answer different questions. Pressure measurement describes load under the sole; posture<br \/>\ncapture describes position above it. Used together, they show a position and its loading consequence<br \/>\nat the same time, which is more informative than either alone.<\/p>\n<h3>How many cameras does a room need?<\/h3>\n<p>That depends on which views the routine requires. Rear, side and front views each make different<br \/>\nrelationships visible, so the answer follows from the questions the team needs to answer rather than<br \/>\nfrom a standard configuration.<\/p>\n<h3>Does camera placement matter that much?<\/h3>\n<p>Yes. A camera describes what it can see from where it stands, so placement determines which<br \/>\nrelationships appear in the record. Keeping placement set and marked is what makes recordings from<br \/>\ndifferent dates comparable.<\/p>\n<h3>Can posture recordings be compared over time?<\/h3>\n<p>Yes, provided the routine is consistent: the same camera position, the same standing or moving<br \/>\ncondition, the same sequence and the same operator where possible. Consistency is what makes<br \/>\ncomparison possible, and comparison is where the record earns its value.<\/p>\n<h3>Can we start with one system for a single room?<\/h3>\n<p>Yes. The minimum order quantity for machines is one unit, which lets a team trial the routine in<br \/>\ntheir real room before standardising it elsewhere.<\/p>\n<h3>What warranty, testing and support are included?<\/h3>\n<p>A twelve-month machine warranty covering non-human damage with free spare parts within that scope,<br \/>\na seven-day in-house testing period before dispatch, and support through a dedicated WhatsApp group<br \/>\nwith direct engineer access, remote assistance where the setting allows, and over-the-air updates for<br \/>\nconnected units.<\/p>\n<\/div>\n<h2>What we would do next<\/h2>\n<p>Decide which views your routine needs, then place the camera deliberately and keep it there. Read<br \/>\n<a href=\"\/news\/3027\/\">what posture analysis with a foot scanner sees and misses<\/a> before you commit<br \/>\nto a routine, and <a href=\"\/news\/3022\/\">this article on what a gait report shows<\/a> for how the<br \/>\noutput is normally presented. The <a href=\"\/x5-foot-scanner\/\">X5 system<\/a> is our configuration for<br \/>\nfoot, ankle and posture work, and the <a href=\"\/core-technology\/\">technology overview<\/a> explains<br \/>\nhow pressure and camera-based capture combine. For a discussion about your own room,<br \/>\n<a href=\"\/contact\/\">contact the team<\/a>.<\/p>\n<p class=\"fwl-disclaimer\"><em>This article is intended for professional and educational reference.<br \/>\nIt is not medical advice. Foot assessment equipment produces measurements and images; clinical<br \/>\ninterpretation and any decision about care remain the responsibility of a qualified professional.<br \/>\nCertification scope is limited to the documentation we hold: European Union certification and ISO<br \/>\nquality system certification.<\/em><\/p>\n<div class=\"fwl-related\">\n<h2>Related reading<\/h2>\n<ul>\n<li><a href=\"\/news\/3027\/\">Posture analysis with a foot scanner: what the machine sees and what it misses<\/a><\/li>\n<li><a href=\"\/news\/3022\/\">Inside a gait analysis report: what the data shows and what it cannot<\/a><\/li>\n<li><a href=\"\/news\/1243\/\">Podiatry foot analysis tools: what each type is for<\/a><\/li>\n<li><a href=\"\/news\/3020\/\">Putting a walkway gait assessment into a rehabilitation unit<\/a><\/li>\n<li><a href=\"\/x5-foot-scanner\/\">X5 foot, ankle and posture system<\/a><\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/footworklab.net\/posture-analyzer\/#faqpage\",\n  \"mainEntity\": [\n    {\"@type\": \"Question\", \"name\": \"What does a posture analyzer actually record?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Camera-based capture identifies body landmarks and describes how the body is arranged over its base of support: the position of the feet, ankles, knees, pelvis and shoulders across a capture. The output is a set of measurements and images describing position, not an explanation of it.\"}},\n    {\"@type\": \"Question\", \"name\": \"Is posture capture a replacement for pressure measurement?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No, they answer different questions. Pressure measurement describes load under the sole; posture capture describes position above it. Used together, they show a position and its loading consequence at the same time, which is more informative than either alone.\"}},\n    {\"@type\": \"Question\", \"name\": \"How many cameras does a room need?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"That depends on which views the routine requires. Rear, side and front views each make different relationships visible, so the answer follows from the questions the team needs to answer rather than from a standard configuration.\"}},\n    {\"@type\": \"Question\", \"name\": \"Does camera placement matter that much?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. A camera describes what it can see from where it stands, so placement determines which relationships appear in the record. Keeping placement set and marked is what makes recordings from different dates comparable.\"}},\n    {\"@type\": \"Question\", \"name\": \"Can posture recordings be compared over time?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, provided the routine is consistent: the same camera position, the same standing or moving condition, the same sequence and the same operator where possible. Consistency is what makes comparison possible, and comparison is where the record earns its value.\"}},\n    {\"@type\": \"Question\", \"name\": \"Can we start with one system for a single room?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The minimum order quantity for machines is one unit, which lets a team trial the routine in their real room before standardising it elsewhere.\"}},\n    {\"@type\": \"Question\", \"name\": \"What warranty, testing and support are included?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A twelve-month machine warranty covering non-human damage with free spare parts within that scope, a seven-day in-house testing period before dispatch, and support through a dedicated WhatsApp group with direct engineer access, remote assistance where the setting allows, and over-the-air updates for connected units.\"}}\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Camera-based capture describes position above the sole, which pressure data alone cannot reach. Placement, routine and the limits.<\/p>","protected":false},"author":1,"featured_media":3125,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-3099","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/3099","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/comments?post=3099"}],"version-history":[{"count":2,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/3099\/revisions"}],"predecessor-version":[{"id":3128,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/3099\/revisions\/3128"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/media\/3125"}],"wp:attachment":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/media?parent=3099"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/categories?post=3099"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/tags?post=3099"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}