{"id":5792,"date":"2026-11-16T21:38:18","date_gmt":"2026-11-17T09:38:18","guid":{"rendered":"https:\/\/footworklab.net\/?p=5792"},"modified":"2026-11-16T21:38:18","modified_gmt":"2026-11-17T09:38:18","slug":"calibration-care-comparable-record","status":"publish","type":"post","link":"https:\/\/footworklab.net\/es\/news\/5792\/","title":{"rendered":"Calibration, Care and a Record That Stays Comparable"},"content":{"rendered":"<div class=\"fwl-author\">\n<p><strong>About the author<\/strong> \u2014 FOOTWORK LAB builds foot assessment equipment and custom orthotic insoles at its own plant in Ruichang, Jiangxi Province, China. The company was founded in 2014 and has been producing at that plant since 2018; we make what we sell instead of trading in it, and we hold European Union certification and ISO quality system certification. The service questions below come up every time we set up at the Canton Fair or at exhibitions in Dubai, Vietnam, Brazil and Hong Kong, where owners who have run a unit for a season or longer ask what it takes to keep this year&#8217;s records readable against last year&#8217;s. <a href=\"\/our-factory\/\">See the factory<\/a> or <a href=\"\/certificate\/\">view certification<\/a>.<\/p>\n<\/div>\n<p class=\"fwl-lead\"><strong>The clinic bought its platform two winters ago, and the owner rang to ask whether the records from the first season could still be trusted alongside the ones being printed this week.<\/strong> Nothing had gone wrong. The machine turned on, the reports printed, the customers kept their appointments. What had changed was quieter: a new member of staff had joined the cleaning rota, a software update had arrived over the network, and the room had been rearranged around a new cabinet. Each of those is a small event, and each of them touches the one thing a foot pressure platform is actually bought for, which is not the picture on the screen but the comparability of its records across time. A foot pressure platform calibration question is, in practice, a question about habits: what the room checks each morning, what it cleans and how, when it stops and calls for help, and how the files are stored so that a record taken today means the same thing next year as it means now. This article works through those habits in the order they occur, from the daily routine at the desk to the conversation about replacing a unit, and it is deliberately honest about the edges, including what we do not promise about accuracy and why.<\/p>\n<h2>Comparability is a maintenance outcome, not a purchase<\/h2>\n<p>The useful way to think about a pressure platform is as an instrument that holds its meaning only while its conditions hold. On the day it is installed, every record it produces speaks one language: the same zero, the same surface, the same way of turning load into numbers and images. From that day forward, everything that touches the unit \u2014 dust, cleaning fluid, a cabinet moved against the frame, an operator&#8217;s elbow, a cable kicked on the way past \u2014 is either preserving that language or slowly editing it. The editing is never dramatic. Nothing stops working; the reports keep printing and the values keep having names. What drifts is the assumption underneath the comparison, that a number this month means what the same number meant last month.<\/p>\n<p>This is why the maintenance question and the clinical question are the same question. A room that wants to tell a returning customer whether anything has changed since their last visit is asking the equipment to have stayed the same in between, and the equipment will only honour that if the room has kept it so. The alternative \u2014 buying an instrument, running it until something looks wrong, and trusting the records in the meantime \u2014 is common, and it produces folders full of pages that cannot be safely compared with one another, for reasons nobody can name after the fact.<\/p>\n<p>Buyers sometimes ask what a calibration programme would cost them in time, and the honest answer is: very little, because most of it is not calibration in the laboratory sense at all. It is a short list of checks and habits, performed at the start of a day or the end of one, that keep the instrument&#8217;s conditions where they were. The sections below walk that list in the order a working day meets it. None of it requires tools, and none of it requires opening the unit, which is the one thing a room should never do on its own initiative.<\/p>\n<h2>The morning routine: zero, level, and a clean surface<\/h2>\n<p>The first check of the day is the zero. Before the first customer of the morning, with nobody on the surface, the operator runs the zeroing function the software provides and confirms the reading settles at nothing. Zeroing removes the small offsets that accumulate in any measurement system across power cycles and temperature changes, and it takes seconds. What it must not be confused with is a repair: zeroing corrects the baseline, it does not recover a dirty surface or a tilted frame, which is why it comes first, on a clean and level surface, rather than as a fix applied after something looks wrong.<\/p>\n<p>The second check is level. A platform reads the load presented to it, and a unit standing on an uneven floor or resting one corner on a displaced mat presents a slightly tilted stage to every foot that stands on it. Most rooms never look, because the frame sits where the installer left it; the check is simply to glance at the feet and the floor during the morning clean, and to look again whenever anything in the room has moved. Furniture gets shifted in busy rooms constantly, and a cabinet that leans against a platform edge is a change to the measurement that no report will declare on its own.<\/p>\n<p>The third is cleaning, and it is the check with the most wrong advice attached to it. The surface should be wiped with a soft cloth, lightly dampened with a mild, neutral cleaner, and dried before the first session, in front of the customer if hygiene concerns are in the room, which they usually are with barefoot sessions. What should never happen is liquid running into the seams or edges of the unit, sprays directed at the surface, or anything sharper than a cloth used on it. The surface is the sensing part of the instrument, and a scratch or a soaked seam is not a cosmetic problem. <a href=\"\/news\/5499\/\">What the sensors inside a gait system actually are<\/a> explains the hardware in plain terms, and the short version for the cleaning rota is: treat the surface as you would treat a lens.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/c0056ab70da26139c43588f3551c27d8-25.jpg\" alt=\"X3 pressure &amp; force-line system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X3 pressure &amp; force-line system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>Between sessions: the small habits that keep the surface honest<\/h2>\n<p>Between customers, the habits are about what is allowed onto the surface and in what order. Shoes off before stepping on, never the reverse, because grit carried on a sole is the most common source of fine surface damage in a working room. A hand on the chair or rail rather than a hand on the platform when steadying is needed, because a hand loaded onto the surface mid-recording is a load like any other. Nothing placed on the surface between sessions \u2014 not the session sheets, not a cup, not the wipe container \u2014 because the objects that rest on a platform for hours are the ones nobody remembers when a reading looks odd next week.<\/p>\n<p>The end of the day closes the loop. Wipe the surface once more, cover it if a cover was supplied, and leave the area in front of and behind the walkway clear, because the morning&#8217;s first customer will need the run-up and the evening&#8217;s rearranged chairs will have taken it. A short written checklist, laminated and left at the desk, does this job better than memory, for the plain reason that the check is performed most faithfully by whoever is newest, and the newest person has not yet built the memory to skip it.<\/p>\n<p>One habit belongs to the paperwork rather than the room: the log line. Each day the routine is done, someone initials it. The value of that line appears months later, when a record looks unlike its predecessors and the room needs to know whether the instrument&#8217;s conditions changed, and when. A dated initialed sheet answers the question in seconds; an unsupported memory answers it with a shrug, and the shrug then contaminates every comparison in the folder, including the ones taken years apart for reasons that had nothing to do with the instrument at all.<\/p>\n<h2>When to stop and call the engineer<\/h2>\n<p>Most of what goes wrong announces itself politely, and the room&#8217;s job is to notice rather than to repair. Call for support when the zero will not settle, when a standing record taken on a clean empty surface reads as if something were on it, when the same foot produces visibly different contact images across consecutive clean sessions, when the software reports an error that repeats after a restart, or when the surface has suffered any visible damage or any liquid event. None of these is an instruction to open the unit, adjust a cable, or re-seat anything inside; the inside of the instrument is an engineer&#8217;s territory, and a well-meant repair attempt converts a recoverable fault into a difficult one.<\/p>\n<p>What the room can do before calling is gather the facts that make the call useful, and they take minutes. Note what was recorded, on which surface condition, after which routine; keep the sheets from the sessions that looked wrong rather than reprinting them; and try the one permitted reset, which is a full restart with the surface empty and clean. Support that receives a dated description, the sheets in question and the software version on screen can usually diagnose remotely in one conversation; support that receives an adjective cannot, and the days lost are days of records taken on an instrument nobody trusts.<\/p>\n<p>Every unit we ship leaves with the support path already in place: a dedicated group on WhatsApp with the engineers who know the model, direct access rather than a ticket queue, and remote assistance over the network where the room&#8217;s connection allows it. Machines are also covered by a twelve-month warranty for faults not caused by misuse, and <a href=\"\/news\/5590\/\">what a room should ask for after the first year of warranty<\/a> sets out how the relationship continues past that point. The practical summary for the desk is short: notice early, describe precisely, do not open anything, and use the channel that was set up on delivery day.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/c0056ab70da26139c43588f3551c27d8-26.jpg\" alt=\"X3 pressure &amp; force-line system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X3 pressure &amp; force-line system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>Software updates, and what changes and what does not<\/h2>\n<p>Units that stay connected to the network can receive software upgrades over the air, and the question every room asks is whether an upgrade will quietly change what the numbers mean. The honest answer has two halves. An upgrade is not a change to the sensing hardware; the surface reads load the way it read load before the install. What an upgrade can change is the presentation layer: how values are named, how images are arranged on the page, which items appear by default on the report. A record printed before the upgrade and a record printed after it may therefore look different on paper while describing the foot the same way, and a room that does not know this will read a formatting change as a change in the foot.<\/p>\n<p>The defence is documentation rather than refusal. Note the software version on the session sheet, or at least note it when it changes; keep one example report printed by each version the room has used, filed where the operators can reach it; and when a new version arrives, run the first few sessions knowing the pages may be arranged differently. If a display change genuinely alters the meaning of a named value rather than its appearance, that is a version worth asking the engineers about directly, through the same support group that handles faults, before the room&#8217;s older records are compared against the new pages.<\/p>\n<p>There is a related question about updates that rooms under pressure ask more cynically: whether the upgrade can be skipped indefinitely. We would not recommend that. Updates also carry corrections and the occasional new record item, and a room that freezes on an old version for years will eventually meet a support conversation that begins with the version number. The middle path is the workable one: accept updates when the room is quiet, not mid-morning; train the version note into the session sheet at the same time; and keep the example reports. <a href=\"\/news\/5560\/\">Where scanning promises end and measurement begins<\/a> frames the same discipline from the buyer&#8217;s side: know what the instrument claims, and keep the claims and the records in the same conversation.<\/p>\n<h2>Changing equipment: what happens to the old records<\/h2>\n<p>Sooner or later a room replaces a unit or adds a second one, and the question arrives plainly: can the records from the old instrument be compared with the records from the new one? The honest answer deserves to be stated without hedging. Records from two different instruments are not automatically comparable, in the same way that records from two different rooms are not, and any comparison made across that boundary should be treated as indicative rather than settled. The same model helps, because the two units were built to read the same way; it does not make the two pages identical, and a room that quietly folds an old folder into a new instrument&#8217;s history is writing a story its data does not support.<\/p>\n<p>The workable procedure is the one rooms already use for a new patient&#8217;s first visit. Treat the first sessions on the new unit as the start of that instrument&#8217;s own history, taken with the same morning routine, the same instructions and the same hour where the room has kept those fixed. Where an existing customer&#8217;s history matters, take one session on the new unit knowing it will not merge cleanly with the old pages, and let the new instrument&#8217;s records accumulate from that point. For most rooms this costs one transitional appointment per returning customer, and it buys a folder in which every comparison after the transition is honest.<\/p>\n<p>What the transition should not involve is a promise that the new unit&#8217;s numbers will match the old ones closely, in either direction. We do not publish accuracy figures for our instruments, and we do not present a change of unit as a calibration event; the comparability that matters is built by the room, from the routine, the conditions and the notes, and it is built the same way on the new instrument as it was on the old. A room that has kept its session sheets, its version notes and its log lines will find the transition shorter than one that has not, for the simple reason that it knows exactly what conditions its old records were taken under.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/c0056ab70da26139c43588f3551c27d8-27.jpg\" alt=\"X3 pressure &amp; force-line system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X3 pressure &amp; force-line system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>Filing, service history, and the long life of a record<\/h2>\n<p>The last habit is storage, and it decides whether all the discipline above survives. Printouts belong in the customer&#8217;s folder, but the room also needs its own memory: the daily checklist with initials, the software version notes, the support conversations with their dates and outcomes, and the dates of any engineer visit. This is a service history, and it is the document that turns a question like whether anything changed last spring from a memory exercise into a lookup. Rooms that keep it answer those questions in a minute; rooms that do not answer them with folklore.<\/p>\n<p>The customer file should carry the same discipline in miniature. Each record filed with its date, the hour if the room varies it, the operator, and any condition worth knowing \u2014 the surface was newly cleaned, the software was updated that week, the room was rearranged. None of these lines takes more than a moment, and together they are what allow a comparison made two years later to be trusted or, just as usefully, quietly declined. <a href=\"\/news\/5675\/\">How a second record and a re-testing habit are built<\/a> covers the visiting side of the same ledger, and the two habits are the same habit at different scales: write down the conditions under which each page was made.<\/p>\n<p>The lifetime question closes where the purchase began. An instrument that is wiped, zeroed, level-checked and logged, supported by engineers who can assist remotely, kept current on software with the versions noted, and retired with its history intact, produces folders that stay readable for as long as the room keeps them. The equipment produces measurements and images, and what they mean for a person&#8217;s health remains the judgement of a qualified professional; the room&#8217;s contribution to that judgement is a record whose conditions are known, and the routine in this article is how the conditions stay known.<\/p>\n<h2>Frequently asked questions<\/h2>\n<div class=\"fwl-faq\">\n<h3>How often should the measurement surface be cleaned?<\/h3>\n<p>Before the first session of the day and again at close of business, with a soft cloth lightly dampened in a mild neutral cleaner, dried before use. Sprays and running liquid are the enemy, because seams are the vulnerable part. Between sessions, nothing rests on the surface.<\/p>\n<h3>What does zeroing do, and when should it be run?<\/h3>\n<p>Zeroing removes small accumulated offsets so the baseline reads nothing with an empty surface. Run it each morning before the first customer, on a clean and level surface. It corrects the baseline only; it does not recover a dirty or damaged sensing surface.<\/p>\n<h3>Does a software update change the measurements?<\/h3>\n<p>An update does not change how the surface senses load. It can change how values are named and how reports are arranged, so pages printed before and after may look different while describing the same foot. Note the version on the session sheet and keep an example report per version.<\/p>\n<h3>Can records from an old unit be compared with a new one?<\/h3>\n<p>Not automatically, and any such comparison should be treated as indicative rather than settled. The workable procedure is to start the new instrument&#8217;s own history with the first sessions on it, and to accept one transitional appointment per returning customer.<\/p>\n<h3>What signs mean it is time to call the engineer?<\/h3>\n<p>A zero that will not settle, visibly inconsistent contact images across clean consecutive sessions, repeated software errors after a restart, and any visible surface damage or liquid event. Describe precisely, keep the sheets, and do not open the unit.<\/p>\n<h3>Do you publish accuracy figures or offer laboratory-grade calibration?<\/h3>\n<p>We do not publish accuracy figures for our instruments. Every unit passes a seven-day test before it leaves the factory, and comparability afterwards is built by the room: the daily routine, the conditions written on the sheets, and engineer support when something drifts.<\/p>\n<h3>What support continues after the warranty year?<\/h3>\n<p>The dedicated WhatsApp group with direct engineer access continues, along with remote assistance and over-the-air upgrades where the unit is connected. The twelve-month warranty covers faults not caused by misuse, and the first-year conversation sets out what follows it.<\/p>\n<\/div>\n<h2>What we would do next<\/h2>\n<p>Print the morning routine as a one-page checklist, laminate it, and put it where the newest person on the rota cannot miss it; add an initial line and a version note to the session sheet the same week. Then open the folder where support conversations live and confirm the WhatsApp group for this unit still has its engineers in it, because the channel is only useful on the day it is needed. The <a href=\"\/x3-foot-pressure-scanner\/\">X3 system page<\/a> lists the record items and session types in the equipment&#8217;s own terms, and the <a href=\"\/faq\/\">FAQ page<\/a> carries the service answers we give most often by message.<\/p>\n<p class=\"fwl-disclaimer\"><em>This article is intended for professional and educational reference. It is not medical advice. Foot assessment equipment produces measurements and images; clinical interpretation and any decision about care remain the responsibility of a qualified professional. Certification scope is limited to the documentation we hold: European Union certification and ISO quality system certification.<\/em><\/p>\n<div class=\"fwl-related\">\n<h2>Related reading<\/h2>\n<ul>\n<li><a href=\"\/news\/5560\/\">Scanning Technology: Where Promise Ends and Measurement Begins<\/a><\/li>\n<li><a href=\"\/news\/5675\/\">The Second Record: How a Re-Testing Habit Is Built<\/a><\/li>\n<li><a href=\"\/news\/5610\/\">A Foot Assessment Report, Page by Page<\/a><\/li>\n<li><a href=\"\/news\/5535\/\">The Unpacking List: What to Look At Before the Spec Sheet<\/a><\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/footworklab.net\/calibration-care-comparable-record\/#faqpage\",\n  \"mainEntity\": [\n    {\"@type\": \"Question\", \"name\": \"How often should the measurement surface be cleaned?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Before the first session of the day and again at close of business, with a soft cloth lightly dampened in a mild neutral cleaner, dried before use. Sprays and running liquid are the enemy, because seams are the vulnerable part. Between sessions, nothing rests on the surface.\"}},\n    {\"@type\": \"Question\", \"name\": \"What does zeroing do, and when should it be run?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Zeroing removes small accumulated offsets so the baseline reads nothing with an empty surface. Run it each morning before the first customer, on a clean and level surface. It corrects the baseline only; it does not recover a dirty or damaged sensing surface.\"}},\n    {\"@type\": \"Question\", \"name\": \"Does a software update change the measurements?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"An update does not change how the surface senses load. It can change how values are named and how reports are arranged, so pages printed before and after may look different while describing the same foot. Note the version on the session sheet and keep an example report per version.\"}},\n    {\"@type\": \"Question\", \"name\": \"Can records from an old unit be compared with a new one?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Not automatically, and any such comparison should be treated as indicative rather than settled. The workable procedure is to start the new instrument's own history with the first sessions on it, and to accept one transitional appointment per returning customer.\"}},\n    {\"@type\": \"Question\", \"name\": \"What signs mean it is time to call the engineer?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A zero that will not settle, visibly inconsistent contact images across clean consecutive sessions, repeated software errors after a restart, and any visible surface damage or liquid event. Describe precisely, keep the sheets, and do not open the unit.\"}},\n    {\"@type\": \"Question\", \"name\": \"Do you publish accuracy figures or offer laboratory-grade calibration?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"We do not publish accuracy figures for our instruments. Every unit passes a seven-day test before it leaves the factory, and comparability afterwards is built by the room: the daily routine, the conditions written on the sheets, and engineer support when something drifts.\"}},\n    {\"@type\": \"Question\", \"name\": \"What support continues after the warranty year?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The dedicated WhatsApp group with direct engineer access continues, along with remote assistance and over-the-air upgrades where the unit is connected. The twelve-month warranty covers faults not caused by misuse, and the first-year conversation sets out what follows it.\"}}\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"Calibration, Care and a Record That Stays Comparable\",\n  \"author\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"about\": {\"@type\": \"Thing\", \"name\": \"foot pressure platform calibration\"},\n  \"mainEntityOfPage\": \"https:\/\/footworklab.net\/calibration-care-comparable-record\/\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A record from last year is only useful if this year&#8217;s machine still measures the same way. The checks that keep two records in one language.<\/p>","protected":false},"author":1,"featured_media":5789,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-5792","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/5792","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/comments?post=5792"}],"version-history":[{"count":1,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/5792\/revisions"}],"predecessor-version":[{"id":5793,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/5792\/revisions\/5793"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/media\/5789"}],"wp:attachment":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/media?parent=5792"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/categories?post=5792"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/tags?post=5792"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}