{"id":6040,"date":"2026-11-18T21:34:06","date_gmt":"2026-11-19T09:34:06","guid":{"rendered":"https:\/\/footworklab.net\/?p=6040"},"modified":"2026-11-18T21:34:06","modified_gmt":"2026-11-19T09:34:06","slug":"capture-protocol-between-operators","status":"publish","type":"post","link":"https:\/\/footworklab.net\/es\/news\/6040\/","title":{"rendered":"Two Operators, One Protocol: Making Captures Comparable Across Staff"},"content":{"rendered":"<div class=\"fwl-author\">\n<p><strong>About the author<\/strong> \u2014 FOOTWORK LAB is the factory behind the foot assessment equipment and custom orthotic insoles it supplies, not a trading company. The company was founded in 2014, and the plant in Ruichang, Jiangxi Province began production in 2018, where the equipment and the insoles are developed and manufactured in-house. We hold European Union certification and ISO quality system certification. How to keep two staff members&#8217; captures comparable on one machine is among the questions clinic owners put to us most often at the Canton Fair and at exhibitions in Dubai, Vietnam, Brazil and Hong Kong, usually after they have compared two folders from the same week. <a href=\"\/our-factory\/\">The factory<\/a> and <a href=\"\/certificate\/\">certification<\/a>.<\/p>\n<\/div>\n<p class=\"fwl-lead\"><strong>The Monday customer and the Wednesday customer were the same person, same complaint, same shoes, same machine.<\/strong> The records did not match, and the owner wanted to know what the equipment had got wrong. Nothing, as it turned out. Operator A had put a mark on the floor, pointed the customer at a fixed spot on the wall and let her rest fingertips on the rail; operator B worked from feel, hands free, one pass instead of three, and filed whatever the software left on screen. Each ran the session the way they personally run sessions. The machine measured both honestly, which is exactly why the two reports could not be read against each other. A pressure platform does not standardise a room. It records what the room does, under whatever conditions a person standing next to it supplied. When two staff members work from habit instead of a written protocol, the drift shows up quietly: stance position, gaze, rail use, pass counts, which pass gets filed, what the session sheet says. Nothing dramatic, everything cumulative. This article works through the fix the way we walk clinic buyers through it: one page of writing, a handful of fixed phrases, and a monthly habit of pulling folders.<\/p>\n<h2>The machine is the same; the room is not<\/h2>\n<p>Buyers reasonably assume that two rooms running identical equipment will produce comparable records, and are surprised when they do not. The equipment is faithful. It records how plantar pressure arrives and spreads across the sensing surface, it traces the centre of pressure through the load line as the stance holds, and with posture capture running alongside it shows how the foot presented in the frame. Faithful is not the same as standardised. The machine records what happens on it under whatever conditions the room supplied, and the conditions are supplied by a person, every time, whether or not that person knows they are supplying them.<\/p>\n<p>Operator A and operator B run the same session differently without either of them noticing. A places a floor mark and points the customer at it; B relies on judgement. A lets the customer steady fingertips on the rail; B prefers hands free. A takes three standing passes and files the quietest; B takes one and files it. A writes the pass count and the rail note on the sheet; B writes nothing. Every one of those habits is defensible on its own. Assembled into one folder across two visits, they produce two records that look as if they disagree about the same foot, when in fact they describe two different events.<\/p>\n<p>Comparability is the property worth defending here: the ability to set one record beside another and learn something honest from the comparison. It survives only when the conditions around the measurement match. That makes it a writing problem before it is a technology problem, and the fix costs a sheet of paper and a laminating pouch.<\/p>\n<h2>Where the drift actually starts<\/h2>\n<p>The drift is rarely about settings, which the software keeps in one place for everyone. It starts in the small physical decisions each operator makes alone at the machine: where the customer stands and whether a floor mark is used, what the customer looks at during the pass, whether the rail is touched, how the feet are placed, whether an instruction about even loading is said out loud or left to chance. Then it moves to session-level choices: how many passes are taken, which pass is filed, single frame or average, whether footwear and socks come off the same way for every customer, and what the session sheet records, if anything.<\/p>\n<p>Then the report-level choices, which travel furthest: which images reach the printout, whether a conditions line appears at the top of the page, whether the reader of the folder next season can reconstruct the day. None of these decisions is large. Each takes a few seconds. Together they decide whether the folder from Monday and the folder from Wednesday describe the same event or two events wearing the same customer&#8217;s name.<\/p>\n<p>Rooms usually discover this the way the two-operator clinic did: a customer returns, the other staff member takes the new record, and the pages do not match. The conversation starts from the equipment, because the equipment is the visible thing in the room. It almost never ends there. There is legitimate variation even before a second operator enters the picture, as our article on <a href=\"\/news\/5782\/\">the same foot measured at three points in a working day<\/a> sets out. Cross-operator drift stacks a second layer on top of that, and the second layer is the one a protocol can remove.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/4349630b8a2b8ed40782385423aeffbb-3.jpg\" alt=\"X3 pressure &amp; force-line system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X3 pressure &amp; force-line system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>The one-page protocol<\/h2>\n<p>The fix is one page, written, laminated, hung within reach of the machine. Not a manual; a protocol. Six lines is enough: where the customer stands, meaning the floor mark; where the customer looks, meaning one fixed point named in the room; what the hands do, meaning the rail rule; how many passes are taken; which pass is filed; and the sentence the session sheet must carry at the end of every capture.<\/p>\n<p>Written out, the page reads like this: customer stands on the mark, feet placed the same way every time, gaze on the cross on the far wall, hands free unless support is genuinely needed; three standing passes, reset between each; the settled pass is filed, the others stay on the machine; the sheet records pass count, filed pass, rail use, and anything unusual about the day. Every phrase on that page is a decision that used to be made by whichever operator happened to be standing there. Now it is made once, by the room, in advance, and applied the same way to every customer including the difficult ones.<\/p>\n<p>The owner goes first. The most common failure we see is a protocol that the owner quietly exempts themselves from, because they ran the machine before the page existed and their habits feel like the standard. On a busy Saturday their sessions drift, and the folder carries two protocols again. The page exists for everyone who touches the machine, and the person who bought it is on that list.<\/p>\n<h2>Stance marks, rail use and the words staff say<\/h2>\n<p>A floor mark sounds trivial and does real work. It removes the argument about where the customer stood, which is otherwise unanswerable after the fact. Tape on the floor or the mark the room already uses, it does not matter which; what matters is that both operators point at the same one. The gaze point matters even more than it looks, because attention moved off the feet is what settles a restless customer, and a settled customer is what makes the filing rule workable at all. Our piece on <a href=\"\/news\/5840\/\">capturing a record when the customer cannot stand still<\/a> covers the room-side phrases in detail.<\/p>\n<p>The rail rule needs one sentence and one habit: fingertips rest lightly, nobody leans, and whatever the room decides gets written on the page and said the same way every time. Support used silently on Monday and omitted on Wednesday is a condition change nobody recorded, and the two records will be compared anyway by whoever reads them.<\/p>\n<p>The script belongs on the page too. Between passes the operator says the same short things: once more, exactly the same; look at the cross; let your feet settle; breathe normally. Each pass is announced the same way, so the customer learns the rhythm by the second attempt. New staff copy the phrases verbatim for their first weeks. Experienced staff already say them, because a good protocol is written down from what the best operator in the room was already doing, not invented over their head.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/4349630b8a2b8ed40782385423aeffbb-4.jpg\" alt=\"X3 pressure &amp; force-line system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X3 pressure &amp; force-line system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>Bringing a new operator onto the protocol<\/h2>\n<p>The routine that holds in practice has three stages. First, the new operator shadows three full sessions, saying nothing, watching where the mark is, what is said, what gets filed. Second, they run three sessions with a senior operator in the room, correcting nothing, only comparing afterwards against the sheet. Third, they run the next ten alone while those folders get checked against the protocol. By the end of that sequence their records sit inside the room&#8217;s baseline instead of quietly starting a second one, and the correction happens on folders, not on customers.<\/p>\n<p>The equipment side carries its share. Machines leave our plant only after seven days of testing, built on a modular structure so that a part can be replaced without replacing the system. If a room&#8217;s records start drifting in a way the sheet cannot explain, the dedicated WhatsApp support group and remote assistance put a technician in front of the software quickly, and over-the-air updates carry fixes without anyone travelling. What remote help cannot repair is an unwritten protocol. That part has always been the room&#8217;s page, and it is the first thing we ask about when two folders from the same room disagree.<\/p>\n<p>Who runs the scan decides more about record quality than any setting behind the software, which is why the training routine and the page are the same project. A room that treats operator onboarding as an informal handover inherits every habit the departing staff member had, including the ones nobody wrote down.<\/p>\n<h2>Audit the folders, not just the staff<\/h2>\n<p>Once a month, pull ten folders at random and ask three questions of each. Does the conditions line exist on the session sheet. Do the passes and the filing rule match what the protocol page says. Would a reader who was not in the room know under what conditions the record was taken. The audit takes minutes, and it catches drift while drift is still cheap to correct.<\/p>\n<p>Compare across operators deliberately, not accusatorially. The same customer captured by both staff members on different visits, set side by side, is the fastest way to see whether the protocol is holding. Reading a left and right comparison on one screen under the protocol&#8217;s stated conditions tells the room which differences are information about the foot and which are noise introduced by conditions, as our article on <a href=\"\/news\/5860\/\">building a left and right comparison you can defend<\/a> explains. Differences that remain after the conditions match are worth discussing. Differences that come from conditions are not findings at all.<\/p>\n<p>The machine side has its own comparability work, and it is separate: calibration, care and the handling habits that keep a record from this month readable against a record from last season, which our piece on <a href=\"\/news\/5792\/\">calibration, care and a record that stays comparable<\/a> covers. The protocol keeps the human side comparable. Neither substitutes for the other, and a room that does only one will eventually find the gap through a customer.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/4349630b8a2b8ed40782385423aeffbb-5.jpg\" alt=\"X3 pressure &amp; force-line system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB X3 pressure &amp; force-line system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>What a protocol cannot standardise<\/h2>\n<p>Customers differ, days differ, and no page removes that. The protocol standardises conditions, not outcomes: it says how the session is run, not what the foot will do. The record remains a measurement under stated conditions, and the equipment produces measurements and images, while interpretation belongs to a qualified professional. Two operators following the same page will still capture two customers differently, and the same customer differently on a tired Thursday. The page cannot and should not pretend otherwise; it just makes the conditions legible so the reader knows what they are looking at.<\/p>\n<p>Do not over-standardise, either. The customer who genuinely needs the rail, the session that ends in a seated, partially loaded capture, the day when only two passes are possible: a good protocol has a branch for these, and the branch is written on the sheet, not improvised. The page&#8217;s job is to make the exception visible, not to make exceptions impossible.<\/p>\n<p>The point of the page was never uniformity for its own sake. It is that the folder tells the truth about the conditions, so that six months later, when the customer returns and the record gets compared against the old one, the comparison means something. That is the whole return a sheet of paper and a laminating pouch can earn, and in the rooms that keep the habit, it earns it weekly.<\/p>\n<h2>Frequently asked questions<\/h2>\n<div class=\"fwl-faq\">\n<h3>Why do two operators on the same machine produce records that do not match?<\/h3>\n<p>Because the conditions around the capture are human decisions: where the customer stands, where they look, rail use, pass count, which pass is filed, what the sheet says. The equipment records faithfully under whatever conditions are supplied. When those conditions differ, the records describe different events, and only a written protocol keeps them aligned.<\/p>\n<h3>What should a capture protocol page contain?<\/h3>\n<p>Six things: the stance position, the gaze point, the rail rule, the number of passes, the filing rule, and the line the session sheet must carry. One page, laminated, hung near the machine, applied to every operator including the owner. It should be written from the best habits already in the room, not invented separately.<\/p>\n<h3>How do we train a new operator without breaking comparability?<\/h3>\n<p>Shadow three sessions, run three supervised, then run ten alone while the folders are checked against the protocol. Correction happens on folders and sheets, not on customers mid-session. By the end of the sequence the new operator&#8217;s records sit inside the room&#8217;s baseline instead of quietly starting a second one.<\/p>\n<h3>Should the rail be allowed during a standing capture?<\/h3>\n<p>Either rule is defensible; consistency is what matters. Light fingertip support is acceptable and common, leaning is not. Whatever the room decides belongs on the protocol page, gets said the same way every time, and is noted on the session sheet whenever support was actually used, so the condition is never silent.<\/p>\n<h3>How often should folders be audited between operators?<\/h3>\n<p>Monthly is enough in a busy room. Pull ten folders at random and check three things: the conditions line exists, the passes and filing match the protocol, and a reader who was not in the room could reconstruct the conditions. The audit takes minutes and catches drift while it is still cheap to fix.<\/p>\n<h3>Does the equipment itself enforce the protocol?<\/h3>\n<p>No. The equipment records what happens on its surface under the conditions supplied, and it does that faithfully. The software keeps settings consistent, but stance, phrasing, pass counts and filing are decisions people make. The protocol page and the session sheet carry those decisions; the machine carries everything else.<\/p>\n<h3>Can records from two different sites be compared?<\/h3>\n<p>Only if both rooms run the same written protocol and the machine care is current on both sides, and even then the site should be labelled on the record. When a platform moves between sites, a re-check of the conditions is part of settling it in, and the first records afterwards should say so.<\/p>\n<\/div>\n<h2>What we would do next<\/h2>\n<p>Write the page this week rather than agreeing to write it soon: six lines, the room&#8217;s own best habits, laminated, and the owner&#8217;s sessions checked against it first. Pull the last ten folders and see whether the conditions line exists; where it does not, mark the gap honestly instead of comparing across it. Our article on <a href=\"\/news\/5880\/\">belt speed as a protocol decision<\/a> extends the same argument to the walking side of the session, where the same two-operator drift appears in a different costume. The <a href=\"\/x3-foot-pressure-scanner\/\">X3 system page<\/a> describes the pressure and force-line capture in the equipment&#8217;s own terms, the <a href=\"\/faq\/\">FAQ page<\/a> carries the operational answers we give most often by message, and the <a href=\"\/contact\/\">contact page<\/a> reaches the team that helps rooms put their protocol into writing before the machine ships.<\/p>\n<p class=\"fwl-disclaimer\"><em>This article is intended for professional and educational reference. It is not medical advice. Foot assessment equipment produces measurements and images; clinical interpretation and any decision about care remain the responsibility of a qualified professional. Certification scope is limited to the documentation we hold: European Union certification and ISO quality system certification.<\/em><\/p>\n<div class=\"fwl-related\">\n<h2>Related reading<\/h2>\n<ul>\n<li><a href=\"\/news\/5900\/\">Moving a Platform Between Sites: The Re-Check List<\/a><\/li>\n<li><a href=\"\/news\/5890\/\">Two Cameras and One Stride: Keeping Video and Pressure in Step<\/a><\/li>\n<li><a href=\"\/news\/5850\/\">A Short Run-Up and a Low Ceiling: Capturing Gait in a Small Room<\/a><\/li>\n<li><a href=\"\/news\/5845\/\">The First Two Weeks: What a Customer Should Be Asked to Report Back<\/a><\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/footworklab.net\/capture-protocol-between-operators\/#faqpage\",\n  \"mainEntity\": [\n    {\"@type\": \"Question\", \"name\": \"Why do two operators on the same machine produce records that do not match?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Because the conditions around the capture are human decisions: where the customer stands, where they look, rail use, pass count, which pass is filed, what the sheet says. The equipment records faithfully under whatever conditions are supplied. When those conditions differ, the records describe different events, and only a written protocol keeps them aligned.\"}},\n    {\"@type\": \"Question\", \"name\": \"What should a capture protocol page contain?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Six things: the stance position, the gaze point, the rail rule, the number of passes, the filing rule, and the line the session sheet must carry. One page, laminated, hung near the machine, applied to every operator including the owner. It should be written from the best habits already in the room, not invented separately.\"}},\n    {\"@type\": \"Question\", \"name\": \"How do we train a new operator without breaking comparability?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Shadow three sessions, run three supervised, then run ten alone while the folders are checked against the protocol. Correction happens on folders and sheets, not on customers mid-session. By the end of the sequence the new operator's records sit inside the room's baseline instead of quietly starting a second one.\"}},\n    {\"@type\": \"Question\", \"name\": \"Should the rail be allowed during a standing capture?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Either rule is defensible; consistency is what matters. Light fingertip support is acceptable and common, leaning is not. Whatever the room decides belongs on the protocol page, gets said the same way every time, and is noted on the session sheet whenever support was actually used, so the condition is never silent.\"}},\n    {\"@type\": \"Question\", \"name\": \"How often should folders be audited between operators?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Monthly is enough in a busy room. Pull ten folders at random and check three things: the conditions line exists, the passes and filing match the protocol, and a reader who was not in the room could reconstruct the conditions. The audit takes minutes and catches drift while it is still cheap to fix.\"}},\n    {\"@type\": \"Question\", \"name\": \"Does the equipment itself enforce the protocol?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. The equipment records what happens on its surface under the conditions supplied, and it does that faithfully. The software keeps settings consistent, but stance, phrasing, pass counts and filing are decisions people make. The protocol page and the session sheet carry those decisions; the machine carries everything else.\"}},\n    {\"@type\": \"Question\", \"name\": \"Can records from two different sites be compared?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Only if both rooms run the same written protocol and the machine care is current on both sides, and even then the site should be labelled on the record. When a platform moves between sites, a re-check of the conditions is part of settling it in, and the first records afterwards should say so.\"}}\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"Two Operators, One Protocol: Making Captures Comparable Across Staff\",\n  \"author\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"about\": {\"@type\": \"Thing\", \"name\": \"standardising capture between operators\"},\n  \"mainEntityOfPage\": \"https:\/\/footworklab.net\/capture-protocol-between-operators\/\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Habits differ between staff. A short written protocol keeps two records comparable.<\/p>","protected":false},"author":1,"featured_media":6033,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-6040","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/6040","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/comments?post=6040"}],"version-history":[{"count":1,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/6040\/revisions"}],"predecessor-version":[{"id":6042,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/posts\/6040\/revisions\/6042"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/media\/6033"}],"wp:attachment":[{"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/media?parent=6040"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/categories?post=6040"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/footworklab.net\/es\/wp-json\/wp\/v2\/tags?post=6040"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}