{"id":5752,"date":"2026-11-16T21:22:18","date_gmt":"2026-11-17T09:22:18","guid":{"rendered":"https:\/\/footworklab.net\/?p=5752"},"modified":"2026-11-16T21:22:18","modified_gmt":"2026-11-17T09:22:18","slug":"installation-day-commissioning-a-platform","status":"publish","type":"post","link":"https:\/\/footworklab.net\/ru\/news\/5752\/","title":{"rendered":"Installation Day: Commissioning a Pressure Platform in a Clinic"},"content":{"rendered":"<div class=\"fwl-author\">\n<p><strong>About the author<\/strong> \u2014 FOOTWORK LAB builds foot assessment equipment and custom orthotic insoles at its own plant in Ruichang, Jiangxi Province, China. The company was founded in 2014 and has been producing at that plant since 2018; we make what we sell instead of trading in it, and we hold European Union certification and ISO quality system certification. The questions below come up whenever we set up at the Canton Fair or at exhibitions in Dubai, Vietnam, Brazil and Hong Kong, where buyers who have just taken delivery of a platform ask what a good commissioning day looks like, and what it should leave behind in the folder. <a href=\"\/our-factory\/\">See the factory<\/a> or <a href=\"\/certificate\/\">view certification<\/a>.<\/p>\n<\/div>\n<p class=\"fwl-lead\"><strong>The crate was in the middle of the treatment room at nine in the morning, and the first patient was booked for two in the afternoon.<\/strong> That gap \u2014 five hours, in a room that had never held a pressure platform \u2014 is what a commissioning day actually has to fill, and it fills more easily when someone has written down the order of work. Every machine we ship has already been through a full test run at the plant before it goes into the crate; what has not been tested is the room it lands in, and the room is where most of the day&#8217;s surprises live. The floor may not be as level as it looks, the power point may sit where the walkway needs to run, and the camera that pairs with the platform needs a sight line nobody thought about when the furniture was placed. This article works through a commissioning day in the order we suggest to clinics: what the room needs before the crate is opened, the sequence for unboxing, the site checks that still get done even though the machine left the factory tested, the first record that gets kept as a baseline, who signs and who is trained, and the support channels that should be connected on day one, before anyone actually needs them.<\/p>\n<h2>The machine arrives tested; the room does not<\/h2>\n<p>It is worth being precise about what the factory test covers, because it sets the boundary for the day. Before any platform leaves our plant it runs a complete test cycle lasting seven days, exercised the way a working week would exercise it, and it does not ship until that cycle is clean. The electronics, the sensing surface, the software and the report flow have all met each other and behaved. What the test cannot cover is anything about the destination: the floor, the power, the light, the furniture, the operator and the first patient. Those arrive untested, and commissioning is the process of testing them.<\/p>\n<p>This division of labour is why the day should not be spent re-litigating the machine. If the platform shows a fault at the factory it does not leave the factory, so a fault that appears on site almost always has a site-shaped cause: a floor that flexes, a power circuit shared with something that switches, a camera pointed at a window. The commissioning mindset is therefore detective work about the room, not suspicion about the crate. Rooms that start from that assumption finish the day with a working installation and a short list of things the space itself needs to give up \u2014 a rug here, a desk moved back there.<\/p>\n<p>The other thing the day buys, if it is done properly, is a written account of the room. Which socket the platform runs from, where the camera stands, what the floor check showed, what was marked on the wall for stance positions. Six months later, when a record looks different from the ones before it, that page is where the investigation starts. A commissioning day that leaves no paper behind has been enjoyed rather than completed.<\/p>\n<h2>What the room needs before the crate is opened<\/h2>\n<p>The walk-up is the first requirement, and it is the one most often forgotten because it is invisible in the spec. A gait pass needs clear floor in front of and behind the measurement area \u2014 enough for the patient to arrive at a natural pace rather than stepping on at the edge \u2014 and that floor cannot be borrowed from the corridor on busy days. Before anything is unpacked, walk the intended path yourself at a normal walking speed, from the chair to the far wall, and move whatever your shoulder brushes. The furniture that survives this walk is furniture the room can keep.<\/p>\n<p>The floor itself comes second. The platform needs to sit level on a surface that does not flex, and a rug, a sprung floor or a tile laid over an uneven screed will all show up in the record as movement that belongs to the floor and not the foot. A builder&#8217;s spirit level takes a minute and settles the question. The power point should be on a circuit that does not share with heavy equipment that cycles on and off, and the cable route from socket to platform needs to cross the walkway safely or not at all.<\/p>\n<p>Third is the camera&#8217;s position, where one is part of the setup. It needs a clear sight line to the standing and walking positions, lighting that does not put the patient between the lens and a window, and a wall or stand that will not be moved next week when the room is reorganised. Mark the standing positions on the floor and the camera&#8217;s footprint on the wall or floor at the end of the day, so the arrangement can be reproduced after any cleaning or rearrangement. Fitted-out rooms \u2014 the kind that were finished before the machine was ever ordered \u2014 deserve a separate conversation, because <a href=\"\/news\/5555\/\">a measurement system arriving in an already finished room<\/a> has fewer free choices than one installed alongside the fit-out.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/0f4c868a36701fee8f854dd993ed730c-3.jpg\" alt=\"FMP pressure &amp; posture customization system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB FMP pressure &amp; posture customization system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>Opening the crate in an order, not in a rush<\/h2>\n<p>Unboxing has a sequence, and the sequence matters more than the speed. The first look at the contents is not the spec sheet; it is the packing list and the crate itself. Check the outside for damage before anything is lifted out, photograph anything that looks wrong while it still looks wrong, and keep every piece of packaging until the installation is signed off, because a machine that has to travel again \u2014 to another room, another floor, another clinic \u2014 travels in the packing it was born in.<\/p>\n<p>Inside, the order is frame first, then accessories, then paperwork. The platform comes out and is positioned where the room check said it should go, before cables and mounts are fitted, because repositioning a cabled machine is twice the work of positioning a bare one. Accessories are counted against the list the moment they are out \u2014 camera, stands, cables, power lead, the small items that live in pockets in the packing \u2014 and paperwork goes in one place, not in three. The temptation at this stage is to power up as soon as something plugs in, and it should be resisted for one more paragraph.<\/p>\n<p>We publish a fuller version of this sequence as a checklist, and rooms that follow it tend to reach the first power-up with everything present rather than everything almost present. <a href=\"\/news\/5535\/\">The unboxing checklist: what to look at before the spec sheet<\/a> covers that list item by item, and the two habits worth stealing from it are the photographs at the door and the packaging kept whole. Both cost nothing on the day, and both are priceless on the one day in fifty when something arrives wrong or has to be moved again.<\/p>\n<h2>The site checks that still get done, every time<\/h2>\n<p>The platform left the plant after seven days of testing, and it still gets checked on arrival, because transport is a real event rather than an abstraction. Crates are lifted, tilted, vibrated for days and occasionally dropped, and a connection that held at the plant may have worked loose in a container. The site verification is short \u2014 it is not a re-run of the factory cycle \u2014 and it follows a fixed order so that nothing is assumed.<\/p>\n<p>Power up and let the system run its own start-up checks first. Then check the zero: with nobody on the surface, the platform should read no load, and if it does not, the operator knows it now rather than in front of a patient. Then the level check, confirmed on the installed surface rather than assumed from the floor check done before unpacking. Then a known walk: someone from the clinic walks the pass a few times, and the record is looked at, not just printed. The camera, where fitted, is aimed and focused on the marked standing positions, and a posture frame is taken to confirm the two pages of the report line up.<\/p>\n<p>None of this duplicates the factory test; it confirms that factory and destination agree. The distinction is worth explaining to the room&#8217;s owner, because buyers sometimes hear &#8220;checked on site&#8221; as doubt about the machine, and it is not. It is the same logic as checking the alignment of a car after a long ferry crossing: nothing is suspected, and everything is confirmed. The checks also produce the last line of the room&#8217;s written account \u2014 date, who ran them, what they showed \u2014 which closes the loop that the room survey opened.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/adc4e0dd68e5bafe7eb2c0618649fed1-2.jpg\" alt=\"FMP pressure &amp; posture customization system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB FMP pressure &amp; posture customization system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>The first record, kept as the baseline<\/h2>\n<p>Once the checks are clean, the day should end with one deliberate act: a record taken properly, filed, and labelled as the installation baseline. The subject matters less than the conditions \u2014 one or two staff members walking at a settled pace, the room as it will actually run, the full session rather than a hurried demonstration. This record becomes the reference the room compares against, not for the person in it, but for the machine in the room: if a question ever arises about whether the platform still behaves as it did on day one, the baseline is the record that answers it.<\/p>\n<p>The baseline also serves training, which is the quieter reason to take it on the day. The staff who will operate the system should each run a session themselves during commissioning \u2014 standing pass, walking passes, report, filing \u2014 while the procedure is fresh and the installer or the engineer on the call is still reachable. A baseline taken by a trainee is worth more than a demonstration taken by a visitor, because it proves the routine runs without the person who set it up standing in the room.<\/p>\n<p>Label the file clearly and store it where the room&#8217;s records live, not on a desktop someone will clean up. Months later, when the question is whether a change came from the patient or the room, the baseline is what the comparison runs against \u2014 the same logic that makes a retest habit valuable for patients applies to the machine&#8217;s own history. Rooms that skip the baseline are not in danger of anything dramatic; they simply lose the one record that would have settled a later argument in a minute.<\/p>\n<h2>Who signs, and who is trained<\/h2>\n<p>A commissioning day should end with two names on paper. The first is the sign-off: the person accepting the installation on the clinic&#8217;s side confirms, in writing, that the room checks were done, the site verification passed, and the accessories listed on the packing list are present. The second is the operator list: the named people who were trained on the day, and the date. Both live in the same folder as the room account and the baseline record. Together they are the evidence of what the room agreed to on day one, which is exactly what everyone forgets gradually and nobody can reconstruct later.<\/p>\n<p>Training on the day should aim at the routine, not at the manual. The operators who will run the room need to be fluent in the session sequence, the stance instructions, the discard habits at the desk and the filing, because those are the parts that get improvised under queue pressure. Deeper technical questions \u2014 what a specific setting does, what a warning message means \u2014 should be answered and then written into the room&#8217;s own one-page quick reference, in the room&#8217;s own words. <a href=\"\/news\/5580\/\">Who should run the scan, and how staff are trained for it<\/a> covers the operator question in depth, and the short version is that a room with two trained operators and one rehearsed script outperforms a room with one confident enthusiast and no script.<\/p>\n<p>Handover is complete when a stranger to the installation could pick up the folder and run the room: the room account, the check results, the baseline, the sign-off, the operator list, the quick reference. That folder is what the warranty conversation and the support conversation will both ask for, and assembling it on the day takes twenty minutes. Assembling it a year later takes a search through five inboxes.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/footworklab.net\/wp-content\/uploads\/2026\/11\/31808f8d9a4722fa4e1e74ab14f34a16-4.jpg\" alt=\"FMP pressure &amp; posture customization system in production \u2014 FOOTWORK LAB\" loading=\"lazy\" title=\"\"><figcaption>FOOTWORK LAB FMP pressure &amp; posture customization system. Product photography of our own output \u2014 specifications are confirmed in writing before an order.<\/figcaption><\/figure>\n<h2>Connecting the support channels before you need them<\/h2>\n<p>The last part of the day costs the least and pays the longest: connecting the support channels while nothing is wrong. Every machine we ship carries a twelve-month warranty, with parts supplied free of charge for faults that are not man-made, and behind the warranty sits a named support arrangement \u2014 a dedicated group on WhatsApp with our engineers directly in it, and remote assistance available when a screen needs to be seen rather than described. The clinic&#8217;s side of that arrangement should be set up on commissioning day: the group created, the machine&#8217;s details written into it, and one person at the clinic named as the point of contact so that questions do not arrive from five directions at once.<\/p>\n<p>The network connection deserves the same treatment. A platform that stays online can receive software upgrades over the air, which means the room picks up improvements without a visit, and it means our engineers can look at a genuine fault directly instead of working from a description of it. Some clinics hesitate to connect a machine to the network on principle, and the hesitation is worth a conversation rather than a shrug: if the room decides to stay offline, the upgrade path and the remote diagnostics narrow, and the trade-off should be a decision written on the room account rather than an accident of the router.<\/p>\n<p>The habit that makes the support arrangement work is the same one that makes the record habit work: write things down at the moment they happen. When a message appears on the screen, photograph it and post it to the group rather than paraphrasing it from memory tomorrow. When something changes in the room \u2014 a desk moved, a cable re-routed, a new heater installed under the platform \u2014 say so in the group. <a href=\"\/news\/5590\/\">What to expect from warranty and after-sales once the first year is over<\/a> continues this story past the warranty period, and the rooms it describes as easiest to help are always the ones whose day-one folder was never allowed to go stale.<\/p>\n<h2>Frequently asked questions<\/h2>\n<div class=\"fwl-faq\">\n<h3>Does the machine need testing on site if it was tested at the factory?<\/h3>\n<p>Yes, and the two tests answer different questions. Every platform runs a seven-day test cycle at our plant before shipping; the site check confirms that transport changed nothing and that the room agrees with the machine \u2014 power, level, zero, a known walk, and the camera alignment where one is fitted. It takes a fraction of the factory cycle and it is done with the room running as it will actually run.<\/p>\n<h3>How much floor space does the installation need?<\/h3>\n<p>Enough for the platform plus a clear walkway in front of and behind it, so patients can arrive at a natural pace instead of stepping on at the edge, plus the camera&#8217;s position where one is fitted. The practical test is to walk the intended path at normal speed before unpacking and move whatever the shoulder brushes.<\/p>\n<h3>What should be kept from the packing?<\/h3>\n<p>Everything, until the installation is signed off. The packing is what the machine travels in if it ever moves again \u2014 another room, another floor, another clinic. Count accessories against the packing list as they come out, photograph any transit damage at the door, and file the paperwork in one place.<\/p>\n<h3>Why keep a baseline record on installation day?<\/h3>\n<p>It is the reference the room compares against later. If a question ever arises about whether the platform still behaves as it did on day one, the baseline settles it. Taken by a trainee rather than a visitor, it doubles as proof that the routine runs without the installer in the room.<\/p>\n<h3>Who should be trained, and to what level?<\/h3>\n<p>At least two named operators, trained to fluency in the session routine: the sequence, the stance instructions, discarding hurried passes at the desk, and filing. Technical settings and warning messages go into a one-page quick reference written in the room&#8217;s own words. Both the sign-off and the operator list are dated and filed.<\/p>\n<h3>Should the platform be connected to the network?<\/h3>\n<p>Connecting keeps two doors open: over-the-air software upgrades, and remote assistance where our engineers can see a fault directly instead of working from a description. A room that decides to stay offline narrows both, and that decision should be made deliberately and written on the room account rather than left to the router.<\/p>\n<h3>What does the warranty cover, and how is support reached?<\/h3>\n<p>Twelve months, with parts supplied free of charge for faults that are not man-made. Support runs through a dedicated WhatsApp group with our engineers directly in it, plus remote assistance when a screen needs to be seen. The clinic names one point of contact on day one, and photographs whatever the screen shows at the moment it shows it.<\/p>\n<\/div>\n<h2>What we would do next<\/h2>\n<p>Print the commissioning sequence as a one-page checklist and keep it in the crate with the packing list, so the day runs in an order rather than in a mood. Then insist on the three filings before anyone goes home: the room account, the baseline record, and the signed operator list. <a href=\"\/news\/5525\/\">The conditions a new insole lab should meet before it opens<\/a> covers the same discipline for rooms adding production alongside assessment, and <a href=\"\/news\/5560\/\">where scanning promises end and measurement begins<\/a> is useful background for the owner deciding what the machine is for. The <a href=\"\/f2-fmp-gait-scanner\/\">FMP system page<\/a> describes the platform and its session types in the equipment&#8217;s own terms, and the <a href=\"\/professional-services\/\">professional services page<\/a> sets out the support arrangements that connect on the day.<\/p>\n<p class=\"fwl-disclaimer\"><em>This article is intended for professional and educational reference. It is not medical advice. Foot assessment equipment produces measurements and images; clinical interpretation and any decision about care remain the responsibility of a qualified professional. Certification scope is limited to the documentation we hold: European Union certification and ISO quality system certification.<\/em><\/p>\n<div class=\"fwl-related\">\n<h2>Related reading<\/h2>\n<ul>\n<li><a href=\"\/news\/5535\/\">The Unboxing Checklist: What to Look at Before the Spec Sheet<\/a><\/li>\n<li><a href=\"\/news\/5555\/\">A Foot Measurement System in an Already Finished Room<\/a><\/li>\n<li><a href=\"\/news\/5580\/\">Who Runs the Scan: Staff Training at the Counter<\/a><\/li>\n<li><a href=\"\/news\/5590\/\">Warranty and After-Sales: What the Second Year Asks For<\/a><\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/footworklab.net\/installation-day-commissioning-a-platform\/#faqpage\",\n  \"mainEntity\": [\n    {\"@type\": \"Question\", \"name\": \"Does the machine need testing on site if it was tested at the factory?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, and the two tests answer different questions. Every platform runs a seven-day test cycle at our plant before shipping; the site check confirms that transport changed nothing and that the room agrees with the machine \u2014 power, level, zero, a known walk, and the camera alignment where one is fitted. It takes a fraction of the factory cycle and it is done with the room running as it will actually run.\"}},\n    {\"@type\": \"Question\", \"name\": \"How much floor space does the installation need?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Enough for the platform plus a clear walkway in front of and behind it, so patients can arrive at a natural pace instead of stepping on at the edge, plus the camera's position where one is fitted. The practical test is to walk the intended path at normal speed before unpacking and move whatever the shoulder brushes.\"}},\n    {\"@type\": \"Question\", \"name\": \"What should be kept from the packing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Everything, until the installation is signed off. The packing is what the machine travels in if it ever moves again \u2014 another room, another floor, another clinic. Count accessories against the packing list as they come out, photograph any transit damage at the door, and file the paperwork in one place.\"}},\n    {\"@type\": \"Question\", \"name\": \"Why keep a baseline record on installation day?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is the reference the room compares against later. If a question ever arises about whether the platform still behaves as it did on day one, the baseline settles it. Taken by a trainee rather than a visitor, it doubles as proof that the routine runs without the installer in the room.\"}},\n    {\"@type\": \"Question\", \"name\": \"Who should be trained, and to what level?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"At least two named operators, trained to fluency in the session routine: the sequence, the stance instructions, discarding hurried passes at the desk, and filing. Technical settings and warning messages go into a one-page quick reference written in the room's own words. Both the sign-off and the operator list are dated and filed.\"}},\n    {\"@type\": \"Question\", \"name\": \"Should the platform be connected to the network?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Connecting keeps two doors open: over-the-air software upgrades, and remote assistance where our engineers can see a fault directly instead of working from a description. A room that decides to stay offline narrows both, and that decision should be made deliberately and written on the room account rather than left to the router.\"}},\n    {\"@type\": \"Question\", \"name\": \"What does the warranty cover, and how is support reached?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Twelve months, with parts supplied free of charge for faults that are not man-made. Support runs through a dedicated WhatsApp group with our engineers directly in it, plus remote assistance when a screen needs to be seen. The clinic names one point of contact on day one, and photographs whatever the screen shows at the moment it shows it.\"}}\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"Installation Day: Commissioning a Pressure Platform in a Clinic\",\n  \"author\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"FOOTWORK LAB\", \"url\": \"https:\/\/footworklab.net\/\"},\n  \"about\": {\"@type\": \"Thing\", \"name\": \"foot scanner installation day\"},\n  \"mainEntityOfPage\": \"https:\/\/footworklab.net\/installation-day-commissioning-a-platform\/\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The machine arrives tested; the room does not. What a commissioning day should cover before the first patient is booked.<\/p>","protected":false},"author":1,"featured_media":5749,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-5752","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/posts\/5752","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/comments?post=5752"}],"version-history":[{"count":1,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/posts\/5752\/revisions"}],"predecessor-version":[{"id":5753,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/posts\/5752\/revisions\/5753"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/media\/5749"}],"wp:attachment":[{"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/media?parent=5752"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/categories?post=5752"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/footworklab.net\/ru\/wp-json\/wp\/v2\/tags?post=5752"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}